PRINT NOGEN QMSTAT TITLE 'QMSTAT - Return MQ subsystems' QMSTAT AMODE 31 QMSTAT RMODE ANY QMSTAT CSECT BAKR R14,R0 Linkage stack LAE R12,0(R15,0) Set R12 as base register ... USING QMSTAT,R12 ... and address it STM 14,12,12(13) Save callers registers LR 15,13 Load R15 with there area BAS 13,PRGMSAVE+END_EYECATCHER Skip around eyecatcher PRGMSAVE DC 18F'0' * ** Assembly Information Follows * ASLCSECT DC CL8'QMSTAT ' **** CSECT name **** ASLMODV DC CL8'1.2' **** Version Info **** DC CL24'WRITTEN BY K E FERGUSON ' DC CL24'COPYRIGHT - Freeware ' ASLASMD DC CL8'&sysdate' **** Assemble date **** ASLASMT DC CL6'&systime' **** Assembly time **** END_EYECATCHER EQU *-PRGMSAVE ST 13,8(15) Setup save area crossing ST 15,4(13) Setup save area crossing XR R3,R3 Clear R3 L R2,0(R1) Preserve parms LH R3,0(R2) Get the parms LTR R3,R3 Do we have any? BZ DO_it No - Just list them all C R3,=F'4' Check length for 4 BE Parm_Length_good WTO 'Invalid parameter passed. Abend S0C3' ABEND EX R15,ABEND Parm_Length_good DS 0H LA R2,2(R2) Point to the parms DO_it DS 0H L R5,CVTPTR Point to CVT ... USING CVT,R5 ... and establish addressability L R11,CVTJESCT Get CVT entry for JESCT ... USING JESCT,R11 ... and address it DROP R5 Finished with CVT L R5,JESSSCT Get SSCT address ... USING SSCT,R5 ... and establish addressability SSCT_Loop DS 0H CLC SSCTID,=C'SSCT' Make sure we point to SSCT BNE Logic_error Error out if we don't L R6,SSCTSUSE Load user area LTR R6,R6 Do we have one? BZ Next_SSCT No - branch to step up SSCT TM SSCTSUSE,b'10000000' Is the SSCTSUSE usable? BO Next_SSCT No - branch to step up SSCT CLC 4(4,R6),=C'ERLY' Is it early load code? BNE Next_SSCT No - branch to step up SSCT CLC 84(8,R6),=C'CSQ3EPX ' Is it MQ Series early load? BNE Next_SSCT No - branch to step up SSCT LTR R3,R3 Testing for active? BZ Skip_Compare CLC 0(4,R2),SSCTSNAM Is it ours? BNE Next_SSCT No - Move along Skip_Compare DS 0H MVC Wtp_MSQ+17(4),SSCTSNAM Move name to Write to Op MVC Wtp_MSQ+8(8),=C' Active' L R7,SSCTSSVT Get the SSVT address L R4,4(R7) LTR R4,R4 Do we have one? BNZ SubSys_Active Yes - Subsystem is active MVC Wtp_MSQ+8(8),=C'Inactive' LTR R3,R3 Looking for one? BZ SubSys_Active No _ keep on going LA R3,8 Set B Exit_Loop SubSys_Active DS 0H LTR R3,R3 Doing the check? BZ Next_RIB No - Get next RIB XR R3,R3 Clear R3 as return code ... B Exit_loop ... and get out Next_RIB DS 0H L R7,128(R6) Get the RIB address MVC Wtp_MSQ+34(8),25(R7) Move version number to WTO MVC Wtp_MSQ+47(7),60(R7) Move last PTF to WTO XR R8,R8 Clear R8 ICM R8,b'0001',33(R7) Load first byte BAS R10,Convert Convert it to printable ... MVC Wtp_MSQ+59(3),ASLSAV2+5 ... and move it to WTO XR R8,R8 Clear R8 ICM R8,b'0001',34(R7) Load second byte BAS R10,Convert Convert it to printable ... MVC Wtp_MSQ+63(3),ASLSAV2+5 ... and move it to WTO Wtp_MSQ WTO ' Active xxxx - MQ Subsys xxxxxxxx PTF xxxxxxx LVL xxx.X xxx' Next_SSCT DS 0H L R5,SSCTSCTA Next SSCT LTR R5,R5 Do we have one? BNZ SSCT_Loop Yes - Process it LTR R3,R3 Doing one system? Bnz Set_rc12 No - Exit LA R3,4 Set RC=4 B Exit_loop Set_rc12 DS 0H LA R3,12 Set return code ... Exit_loop DS 0H LR R15,R3 Set condition code to 0 ... PR ... and exit program Logic_Error DS 0H MVC Wtp_Logic+8(4),SSCTID Put what we found into WTO ... Wtp_Logic WTO 'xxxx found where SSCT should be' ... issue WTO ... B ABEND ... and then ABEND S0C3 Convert DS 0H ST R8,ASLSAV1 Save passed number in R8 LA R8,ASLSAV1 Get the save area address UNPK ASLSAV2+0(9),0(5,R8) Convert it to printable NC ASLSAV2+0(8),=8X'0F' Force in pack digit... TR ASLSAV2+0(8),=CL16'0123456789ABCDEF' ..and convert it BR R10 ASLSAV1 DS F Save area for supplied number ASLSAV2 DS CL9 Temporary save area for convert *********************************************************************** * REGISTER EQUATES * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * R0 EQU 0 * R1 EQU 1 * R2 EQU 2 * R3 EQU 3 * R4 EQU 4 * R5 EQU 5 * R6 EQU 6 * R7 EQU 7 * R8 EQU 8 R E G E Q S * R9 EQU 9 * R10 EQU 10 EQUATE PREFIX TO NUMERIC SYMBOLS IN ORDER * R11 EQU 11 TO MAKE THE USE OF REGISTER OPERANDS IN * R12 EQU 12 INSTRUCTIONS SELF EXPLANITORY.THIS ALSO * R13 EQU 13 CREATES ENTRIES IN CROSS REFERENCE. * R14 EQU 14 * R15 EQU 15 * *********************************************************************** *** ©Copyright Abbydale Systems LLC. *** *********************************************************************** LTORG IEFJSCVT CVT DSECT=YES IEFJESCT TYPE=DSECT END QMSTAT PUNCH ' MODE AMODE(31)' Binder AMODE statement. PUNCH ' MODE RMODE(ANY)' Binder RMODE statement. PUNCH ' ENTRY QMSTAT' Binder Module entry point. PUNCH ' NAME QMSTAT(R)' BINDER MODULE NAME. END , END OF BINDER INPUT.